Pressure gauge UAM DM2005-U2
Pressure gauge DM2005-U2 is designed to measure the overpressure of non-crystallising liquids, steam, gas that are not aggressive to the materials of parts in contact with the measured medium and to provide an alarm (closing/opening of electrical circuits) when the set pressure limit is reached.
The measured environment must be non-aggressive towards copper alloys.
For aggressive environments, a series of stainless steel devices is used – groups: ammonia, corrosion-resistant.
Pressure gauge DM2005-U2 is made of the following materials as standard: steel case, organic glass, brass alloy mechanism and fitting.
The sensitive element of the device is a Bourdon tube. It responds to changes in pressure.
Description
Case material: steel, stainless steel*
Measuring element material: copper alloy
Glass: organic
Current strength: no more than 1A
Voltage: 220-380V
Power: no more than 30W
Connection of external circuits
III- two opening contacts
IV- two closing contacts
V- two contacts: first is opening, second is closing
VI- two contacts: first is closing, second is opening
|
Diameter size, mm | Accuracy class | Measuring range, MPa | Degree of protection (IP) | Thread |
Connection |
DM2010-U2 |
160 |
1,5 1,0*
|
From 0 to 0,06; 0,1; 0,16; 0,25; 0,4; 0,6; 1,0; 1,6; 2,5; 4; 6; 10; 16; 25; 40; 60;
100* 160* MPa |
ІР40
IP53* IP54* |
М20х1,5 |
Bottom Back* |
*Special version
On request, units of measurement can be ordered in kgs/cm²; bar, atm
The gauges can operate at temperature -50°C to + 60°C
Additional information
Connection | Back (Axial), Bottom (Radial) |
---|---|
Diameter, mm | 160 |
Case material | Steel |
Degree of protection | IP40 |
Thread | M20x1,5 |
Measuring range, MPa | from 0 to 0.06, from 0 to 0.1, from 0 to 0.16, from 0 to 0.25, from 0 to 0.4, from 0 to 0.6, from 0 to 1.0, from 0 to 1.6, from 0 to 10, from 0 to 100, from 0 to 16, from 0 to 160, from 0 to 2.5, from 0 to 25, from 0 to 4, from 0 to 40, from 0 to 6, from 0 to 60 |