Manovacuum gauge UAM DA8008-V-U2-Ks

Vibration-resistant manovacuum gauge DA8008-V-U2-Ks is designed to measure overpressure and vacuum pressure of hydrocarbon gas, water-gas-oil emulsion with hydrogen sulphide and carbon dioxide content up to 25 % by volume, inorganic salts and paraffin waxes up to 10 %.
Manometre DA 8008-V-U2-Ks in standard version is made of the following materials: body – stainless steel, glass – organic, mechanism and fitting – stainless steel.
DA 8008-V-U2-Ks is used in conditions of high vibration, the vibration resistance function is achieved by filling the manovacuum gauge with a vibration-absorbing liquid – glycerin.
The sensitive element of the device is a Bourdon tube. It responds to changes in pressure.

Description

Case material: stainless steel

Measuring element material: stainless steel

Glass: organic (safe multilayer glass)

Diameter size, mm

Accuracy class Measuring range, MPa Degree of protection (IP) Thread

Connection

DА8008-V-U2 Ks i1

100 1,5

1,0*

From -0,1 tо 0,06; 0,15; 0,3; 0,9; 1,5; 2,4 MPа IP54

IP65*

М20х1,5

G1/2

Bottom,

Back

 * Special version

On request, units of measurement can be ordered in kgs/cm²; bar, atm

The gauges can operate at temperature -50°C to + 60°C

Maximum temperature of the measuring environment up to 200°C

Additional information

Connection

Back (Axial), Bottom (Radial)

Diameter, mm

100

Case material

Stainless steel

Measuring range, MPa

from -0.1 to 0.06, from -0.1 to 0.15, from -0.1 to 0.3, from -0.1 to 0.5, from -0.1 to 0.9, from -0.1 to 1.5, from -0.1 to 2.4

Thread

G1/2, M20x1,5

Degree of protection

IP54, IP65

You may also like…